Summa Series Servodrive Product Manual
Basic Settings
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
4-6
IMPORTANT
Panel Operator can only display 5 digits. The value of some adjustment
parameters will be 6 digits or more. The display of the parameter values is as
follows (take the display of parameter value -41943040 as an example).
Sign of top digits
Top two digits
Sign of middle digits
Middle four digits
Bottom four digits
Sign of bottom digits
Only when the value is
with sign or negative
number, "−" is displayed.
Lights when negative number is displayed
The example below shows how to change parameter Pn504 (Deviation Counter Overflow Alarm) from
41943040
to
42943240
.
Step 1
Press [
M
] key several times to select the Parameter Setting Mode.
Step 2
Press [▲] key or [▼] key to select the parameter Pn504.
Step 3
Press [◄] key to display bottom four digits of the current value of Pn504.
Step 4
Press and hold [◄] key for 1 second or more, and then a flashing decimal point will appear at the bottom
right of the 5th digit.
Step 5
Press [◄] key twice, moving the flashing decimal point to the 3rd digit.
Step 6
Press [
▲
] key twice, changing the value of the 3rd digit from
0
to
2
.
Step 7
Press [◄] key four times, moving the flashing decimal point to the 3rd of middle four digits.
Step 8
Press [
▲
] key once, changing the value of the 3rd digit from
1
to
2
.
Step 9
Press and hold [◄] key for 1 second or more to return to the display of the Pn504 parameter value, or
press the [