Summa Series Servodrive Product Manual
Appendix
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
12-20
No.
Index
Name
Range
Unit
Default
When Enabled
Pn333
32B1
Touch probe Signal Inverts
0000
~
0011
-
0000
After restart
Pn333.0: Touch Probe 1 signal invert selection
0
Do not invert Touch Probe 1 signal (take effective when low level)
1
Invert Touch Probe 1 signal (take effective when high level)
Pn333.1: Touch Probe 2 signal invert selection
0
Do not invert Touch Probe 2 signal (take effective when low level)
1
Invert Touch Probe 2 signal (take effective when high level)
Pn333.2: Reserved setting (Do not change).
Pn333.3: Reserved setting (Do not change).
Pn401
32F5
Forward Internal Torque Limit
0 to 350
%
350
Immediately
-
Pn402
32F6
Reverse Internal Torque Limit
0 to 350
%
350
Immediately
-
Pn403
32F7
Forward External Torque
Limit
0 to 350
%
100
Immediately
-
Pn404
32F8
Reverse External Torque Limit
0 to 350
%
100
Immediately
-
Pn405
32F9
Reverse Brake Torque Limit
0 to 350
%
300
Immediately
-
Pn406
32FA
Torque Limit at Main Circuit
Voltage Drop
0 to 100
%
50
Immediately
-