Summa Series Servodrive Product Manual
Appendix
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
12-19
No.
Index
Name
Range
Unit
Default
When Enabled
Pn311
329B
S-Curve Selection
0 to 3
-
0
After restart
To set the transition form of the S-curve.
Pn323
32A7
Overspeed Detection
Threshold
1 to 8000
-
8000
Immediately
A03 alarm occurs if the Motor velocity exceeds this threshold.
Pn331
32AF
Touch Probe Signal Allocation
0000 to 0022
-
0010
After restart
Pn331.0: Touch Probe 1 signal Allocated Pin Number
0
Allocate the signal to CN1-1.
1
Allocate the signal to CN1-3.
2
Use the C-Pulse instead of the allocation.
Pn331.1: Touch probe 2 Signal Allocated Pin Number
0
Allocate the signal to CN1-1.
1
Allocate the signal to CN1-3.
2
Use the C-Pulse instead of the allocation.
Pn331.2: Reserved setting (Do not change).
Pn331.3: Reserved setting (Do not change).
Pn332
32B0
Touch Probe Digital Input
Filtering Time
0 to 1000
10ns
0
Immediately
-