Summa Series Servodrive Product Manual
Installation
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
2-2
2.3
Mounting Hole Dimensions
Use two or three mounting holes to securely mount the Drive to the mounting surface.
To mount the Drive, you will need to prepare a screwdriver that is longer than the depth of the Drive.
ED3S-A5*
~
ED3S-04*
ED3S-08*
~
ED3S-15*
ED3S-20*
~
ED3S-30*
Exterior
2 × M4
5
16
4±0.5
(mounting pitch
)
172
5
28±0.5
(mounting pitch)
38
5
164±
0
.5
(m
ount
ing
pit
ch)
172
5
55±0.5
(mounting pitch)
65
Exterior
2 × M4
5
16
4±0.5
(mounting pitch
)
172
5
85±0.5
(mounting pitch)
95
Exterior
3 × M4
2.4
Mounting Interval
Installing One Drive in a Control Cabinet
Provide enough space around the Drive when installing one Drive in a control cabinet, as is shown in
Figure 2-2.
Figure 2-2
Install one Drive in a control cabinet
≥
50mm
≥
30mm
≥
50mm
≥
30mm
≥
75mm
Wiring allowance
Mounting allowance between mounting plate
and cabinet shall be not less than 6.4 mm
Mounting