Summa Series Servodrive Product Manual
Basic Settings
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
4-8
Monitor Number
Content of Display
Unit
Un015
Load Inertia Percentage
%
Un016
Motor Overload Ratio
%
Un017
Reserved
-
Un018
Reserved
-
Un019
Busbar Voltage
V
Un020
Reserved
-
Un021
Encoder temperature
℃
Un022
Main board temperature
℃
Un023
Fully-closed feedback pulse counter
1 pulse
The status (low level or high level) of input signal allocated to each input terminal is displayed.
Monitor Diagram
Monitor No.
Meaning
7 6 5 4 3 2 1 0
Un005
0: CN1-14 (lit for low level, not lit for high level)
1: CN1-15 (lit for low level, not lit for high level)
2: CN1-16 (lit for low level, not lit for high level)
3: CN1-17 (lit for low level, not lit for high level)
4: CN1-18 (lit for low level, not lit for high level)
Un006
0: HWBB1
1: HWBB2
3: External Encoder input signal C
4: External Encoder input signal B
5: External Encoder input signal A
6: EXT1 (Touch Probe Input 1)
7: EXT2 (Touch Probe Input 2)
Un007
0: CN1-6, 7
1: CN1-8, 9
2: CN1-10, 11
3: CN1-12, 13
NOTE
: Un007 represents the state of the output signal. The optocoupler ON and OFF of each output signal depends
on whether the output signal is inverted:
If the signal is not inverted, lit for turning the optocoupler ON, and not lit for turning the optocoupler OFF.
If the signal is inverted, lit for turning the optocoupler OFF, and not lit for turning the optocoupler ON.
4.1.6
Utility Function Mode
This section describes how to apply the basic operations using the Panel Operator to run and adjust the
Motor.
The following table shows the parameters in the Utility Function Mode.
Function Number Name
Fn000
Alarm trace data display
Fn001
Initialize parameter settings