Summa Series Servodrive Product Manual
Appendix
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
12-45
Controlword (6040h)
This object controls the device and operation mode.
Index
Subindex Name
Data Type Access PDO Mapping
Value
6040h
0
Controlword
UINT16
RW
Yes
0x0000
Bit
Data
Description
0
Switch on
-
1
Enable voltage
-
2
Quick stop
-
3
Enable operation
-
4 to 6
Operation mode specific
-
7
Fault reset
-
8
halt
-
9, 10
Reserved
-
11 to 15
Manufacture specific
-
Bit0 to Bit3, and Bit7: These bits function as the control command for the Servo Drive’s state.
Command
Bit of the controlword
Bit7
Bit3
Bit2
Bit1
Bit0
Transitions
Shutdown
0
-
1
1
0
2, 6, 8
Switch on
0
0
1
1
1
3*
Switch on
0
1
1
1
1
3**
Disable voltage
0
-
-
0
-
7, 9, 10, 12
Quick stop
0
-
0
1
-
7, 9, 10, 11
Disable operation 0
0
1
1
1
5
Enable operation
0
1
1
1
1
4, 16
Fault reset
-
-
-
-
15
The description of Bit4 and Bit5 in PP mode is as following.
Bit5
Bit4
Description
0
0 → 1
Start the next positioning after the current positioning completes (target reached)