12-23
No.
Index
Name
Range
Unit
Default
When Enabled
Pn510
3362
Digital Input Signal
Allocations 2
0000 to 0007
-
0004
After restart
Pn510.0: Allocate signal to CN1-18
0
S-ON
1
P-OT
2
N-OT
3
P-CL
4
N-CL
5
G-SEL
6
HmRef
7
Remote
Pn510.1: Reserved setting (Do not change).
Pn510.2: Reserved setting (Do not change).