Summa Series Servodrive Product Manual
Trial Operation
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
8-3
Step 2
Press [▲] key or [▼] key to select the function number Fn002.
Step 3
Press [◄] key, and Panel Operator displays as below.
Lit for Servo OFF
Not lit for Servo ON
Step 4
Press [
M
] key to Servo ON (supply power to Motor).
Press [
M
] key again to Servo OFF (not supply power to Motor).
Step 5
Press [▲] key or [▼] key to run the Motor in forward or reverse direction.
Press and hold [
▲
] key or [
▼
] key to run the Motor continuously.
Forward rotation
Reverse rotation
Default forward rotation is
clockwise (CW) as viewed from
the load end of the Motor.
Default forward rotation is
counterclockwise (CCW) as viewed
from the load end of the Motor.
NOTE
: The rotation direction of the Motor depends on the setting of Pn001.0 (CCW, CW). The figure above shows
the default setting.
Step 6
Press the [◄] key to return to the display of the Fn002.