Summa Series Servodrive Product Manual
CiA402 Drive Profile
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
6-50
6098h = 23
Home: home switch (HmRef)
Deceleration point: home switch (HmRef)
Deceleration point signal inactive at homing start, not reaching positive limit switch:
Motion Profile
Home switch
Positive limit switch
H
-L
Positive limit switch
Home switch
The HmRef signal is inactive initially, and the Motor starts homing in positive direction at high speed.
If the Motor does not reach the limit switch, it decelerates and changes to run in negative direction at
low speed after reaching the rising edge of the HmRef signal.
After reaching the falling edge of the HmRef signal, the Motor stops.
Deceleration point signal active at homing start, reaching positive limit switch:
Motion Profile
Home switch
Positive limit switch
-L
Positive limit switch
Home switch
-H
H
The HmRef signal is inactive initially, and the Motor starts homing in positive direction at high speed.
If the Motor reaches the limit switch, it automatically changes to run in negative direction at high
speed.
After reaching the rising edge of the HmRef signal, the Motor decelerates and continues to run in
negative direction at low speed.
After reaching the falling edge of the HmRef signal, the Motor stops.