Summa Series Servodrive Product Manual
Tuning
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
9-13
Relevant Parameters
Parameter Setting
Description
When Enabled Classification
Pn106
-
Load Inertia Percentage
Immediately
Adjustment
Pn164
-
Turns for PJOG0
Immediately
Adjustment
Pn165
-
Max Speed for PJOG0
Immediately
Adjustment
Pn167
-
Stop Time for PJOG0
Immediately
Adjustment
Pn168
-
Turns for PJOG1
Immediately
Adjustment
Pn169
-
Max Speed for PJOG1
Immediately
Adjustment
Pn171
-
Stop Time for PJOG1
Immediately
Adjustment
Application Restrictions
You can use the automatic vibration suppression function when using the auto-tuning tool. For details,
refers to the section
9.6.4 Automatic Vibration Suppression
The following functions or applications are not available when using Auto-Tuning Tool:
Gain switch is disabled.
Model Following Control Function is disabled.
Notch Filter is disabled.
Vibration Suppression is disabled.
Load Oscillation Suppression is disabled.
CAUTION
The Auto-Tuning Tool is unavailable in fully-closed loop control.
Operation Procedure: Use the Panel Operator of the Drive
The following are the steps to use the Auto-tuning tool.
Step 1
Press [
M
] key several times to select the Utility Function Mode.
Step 2
Press [▲] key or [▼] key to select the function number Fn017.
Step 3
Press [◄] key, and Panel Operator displays as below.
Lit for that the adaptive
notch filter is enabled