Summa Series Servodrive Product Manual
CiA402 Drive Profile
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
6-14
Object
Bit
Name
Value Description
interpolation
1
Enables interpolation.
8
Halt
0
Enables Bit4
1
Stops the axis according to
Halt Option Code
(605Dh)
Statusword
6041h
10
Target reached
0
Halt (Bit 8 in Controlword) = 0: Target position
not reached
Halt (Bit 8 in Controlword) = 1: Axis decelerates
1
Halt (Bit 8 in Controlword) = 0: Target position
reached.
Halt (Bit 8 in Controlword) = 1: Velocity of axis
is 0.
12
ip mode active
0
Interpolation inactive
1
Interpolation active
13
Following error
0
No following error
1
Following error
15
Homeflag
0
Homing not completed
1
Homing completed
Index Subindex Name
Access Data Type Unit
Range
Default
603F
00
Error Code
RO
UINT16
-
0 to 65535
0
6040
00
Controlword
RW
UINT16
-
0 to 65535
0
6041
00
Statusword
RO
UINT16
-
0 to 0xFFFF
0
6060
00
Modes of
operation
RW
INT8
-
0 to 10
0
6061
00
Modes of
Operation display
RO
INT8
-
0 to 10
0
6062
00
Position Demand
Value
RO
INT32
Reference unit
-2147483648
to 2147483647
-
6063
00
Position Actual
Internal Value
RO
INT32
Encoder unit
-2147483648
to 2147483647
-
6064
00
Position Actual
Value
RO
INT32
Reference unit
-2147483648
to 2147483647
-
6065
00
Following Error
Window
RW
INT32
Reference unit
-2147483648
to 2147483647
1048576
6067
00
Position Window
RW
UINT32
Encoder unit
0 to
4294967295
734
6068
00
Position Window
Time
RW
UINT16
ms
0 to 65535
-