Setup & Operation 10. UPS (Uninterruptible Power Supply)
10.5.4 Replacement of Battery
(1) Shut down Windows, and turn OFF the Controller.
(2) Turn OFF the UPS ON/OFF switch.
(4) Battery Connector
UPS ON/OFF Switch
(5)
(3) Wait for about 1 minute until the high voltage charged area is completely discharged.
Remove four mounting screws, and remove the front cover from the Controller.
(4) Remove the battery connector.
(5) Remove six mounting screws, and remove the battery cover.
(6) Pull out the battery from the Controller.
(7) Remove the U-shaped plate from the front of the battery, and mount it onto a new
battery.
U-shaped Plate
(8) Insert the new battery into the Controller
(9) Secure the battery cover to the Controller with the six mounting screws.
(10) Connect the battery connector.
(11) Secure the front cover to the Controller with the four mounting screws.
(12) Turn ON the UPS ON/OFF switch.
RC420 Rev.9
83
Summary of Contents for RC420
Page 1: ...Rev 9 EM073C1492F ROBOT CONTROLLER RC420 ...
Page 2: ...ROBOT CONTROLLER RC420 Rev 9 ...
Page 12: ...Setup Operation ...
Page 20: ...Setup Operation 1 Safety 10 RC420 Rev 9 ...
Page 30: ...Setup Operation 2 3 Controller Part Names and Functions 20 RC420 Rev 9 ...
Page 50: ...Setup Operation 5 5 Circuit Diagrams EMERGENCY Connector 40 RC420 Rev 9 ...
Page 58: ...Setup Operation 6 3 Pin Assignments STANDARD I O Connector 48 RC420 Rev 9 ...
Page 114: ...Setup Operation 10 UPS Uninterruptible Power Supply 104 RC420 Rev 9 ...
Page 115: ...97 Maintenance This manual contains maintenance procedures for the RC420 Robot Controller ...
Page 116: ...Maintenance RC420 Rev 9 106 ...
Page 138: ...Maintenance 6 Motor Driver Module 128 RC420 Rev 9 ...
Page 170: ...Maintenance 12 Recovering the HDD 160 RC420 Rev 9 ...