Maintenance 5. Switching Power Supply Module
124
RC420 Rev.9
(3) Remove four mounting screws, and
remove the Switching Power Supply
module 2.
On the front side
On the rear side
(4) Remove two mounting screws, and
remove the metal plate from the
Switching Power Supply module 2.
(5) Secure the metal plate to a new
Switching Power Supply module 2 with
the two mounting screws.
Metal Plate
(6) Mount the new Switching Power Supply module 2 in the same position. Then,
secure it with the four mounting screws.
(7) Connect the five connectors to the new Switching Power Supply module 2.
(8) Secure the Bottom Cover to the Controller with the six mounting screws.
(9) Insert the battery into the Controller.
(10) Secure the battery cover to the Controller with the six mounting screws.
(11) Connect the battery connector to the battery.
(12) Connect the connector of the board for display to the front cover.
(13) Secure the front cover to the Controller with the four mounting screws.
(14) Turn ON the UPS ON/OFF switch.
(15) Connect the all the cables to the back of the Controller.
Summary of Contents for RC420
Page 1: ...Rev 9 EM073C1492F ROBOT CONTROLLER RC420 ...
Page 2: ...ROBOT CONTROLLER RC420 Rev 9 ...
Page 12: ...Setup Operation ...
Page 20: ...Setup Operation 1 Safety 10 RC420 Rev 9 ...
Page 30: ...Setup Operation 2 3 Controller Part Names and Functions 20 RC420 Rev 9 ...
Page 50: ...Setup Operation 5 5 Circuit Diagrams EMERGENCY Connector 40 RC420 Rev 9 ...
Page 58: ...Setup Operation 6 3 Pin Assignments STANDARD I O Connector 48 RC420 Rev 9 ...
Page 114: ...Setup Operation 10 UPS Uninterruptible Power Supply 104 RC420 Rev 9 ...
Page 115: ...97 Maintenance This manual contains maintenance procedures for the RC420 Robot Controller ...
Page 116: ...Maintenance RC420 Rev 9 106 ...
Page 138: ...Maintenance 6 Motor Driver Module 128 RC420 Rev 9 ...
Page 170: ...Maintenance 12 Recovering the HDD 160 RC420 Rev 9 ...