Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
Menus 15 to 17
SM-I/O PELV
Unidrive SP Advanced User Guide
311
Issue Number: 10 www.controltechniques.com
This parameter can be used to scale the analog output if so desired.
The parameter required to be represented as an analog signal by the analog output on terminal 12, should be programmed into this parameter.
The parameter required to be represented as an analog signal by the analog output on terminal 10, should be programmed into this parameter.
This parameter can be used to scale the analog output if so desired.
The error status is provided so that only one option error trip is required for each Solutions Module slot. If an error occurs, the reason for the error is
written to this parameter and the drive may produce a ‘SLx.Er’ trip, where x is the slot number. A value of zero indicates that the Solutions Module has
not detected an error, a non-zero value indicates that an error has been detected. (See Table 5-18 on page 304 for the meaning of the values in this
parameter). When the drive is reset, this parameter is cleared for the relevant Solutions Module.
This Solutions Module includes a temperature monitoring circuit. If the PCB temperature exceeds 90
°
C, the drive fan is forced to operate at full speed
(for a minimum of 10s). If the temperature falls below 90
°
C, the fan can operate normally again. If the PCB temperature exceeds 100
°
C, the drive is
tripped and the error status is set to 74.
This module contains two processors, and thus two software versions. Pr
x.02
shows the version number of the main module processor. Pr
x.51
,
which is normally used to give a sub-version number, shows the software version in the slave processor, which operates on the PELV side of the
isolation barrier.
x.45
Analog output 2 scaling
RW
Uni
US
Ú
0.000 to 4.000
Ö
1.000
Update rate: Background read
x.47
Analog output 2 source
RW
Uni
US
Ú
Pr
0.00
to Pr
21.51
Ö
Pr
0.00
Update rate: Read on reset
x.48
Analog output 1 source
RW
Uni
US
Ú
Pr
0.00
to Pr
21.51
Ö
Pr
0.00
Update rate: Read on reset
x.49
Analog output 1 scaling
RW
Uni
US
Ú
0.000 to 4.000
Ö
1.000
Update rate: Background read
x.50
Solutions Module error status
RO
Uni
NC
PT
Ú
0 to 255
Ö
Update rate: Background read
x.51
Solutions Module software sub-version
RO
Uni
NC
PT
Ú
0 to 99
Ö
Update rate: Write on power-up
Summary of Contents for unidrive sp
Page 419: ......
Page 420: ...0471 0002 10 ...