Menu 8
Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
168
Unidrive SP Advanced User Guide
www.controltechniques.com Issue Number: 10
This parameter changes the logic polarity for digital inputs and digital outputs, but not the enable input, the relay output or the 24V output.
When this parameter is zero digital outputs are in push-pull mode. When this parameter is one either the high-side drive (negative logic polarity) or the
low-side driver (positive logic polarity) is disabled. This allows outputs to be connected in a wire-ORed configuration.
8.21
T24 digital I/O 1 source/destination
8.22
T25 digital I/O 2 source/destination
8.23
T26 digital I/O 3 source/destination
8.24
T27 digital input 4 destination
8.25
T28 digital input 5 destination
8.26
T29 digital input 6 destination
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV PT US RW BU PS
1
2
1
1
1
1
Default
Open-loop, Closed-loop vector, Servo
Regen
See Table 5-7 on page 166
See Table 5-8 on page 166
Range
Open-loop, Closed-loop vector, Servo,
Regen
Pr
0.00
to Pr
21.51
Update rate
Read on drive reset
8.27
Relay source
8.28
T22 24V output source
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV PT US RW BU PS
2
1
1
1
1
Default
Open-loop, Closed-loop vector, Servo
Regen
See Table 5-7 on page 166
See Table 5-8 on page 166
Range
Open-loop, Closed-loop vector, Servo,
Regen
Pr
0.00
to Pr
21.51
Update rate
Read on drive reset
8.29
Positive logic select
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV PT US RW BU PS
1
1
1
1
1
Default
Open-loop, Closed-loop vector, Servo,
Regen
On (1)
Update rate
Background read
Pr 8.29 = 0 (negative logic)
Pr 8.29 = 1 (positive logic)
Inputs
<5V = 1, >15V = 0
<5V = 0, >15V = 1
Non-relay Outputs
On (1) = <5V, OFF (0) = >15V
OFF (0) = <5V, On (1) = >15V
Relay outputs
OFF (0) = open, On (1) = closed
OFF (0) = open, On (1) = closed
24V output (T22)
OFF (0) = 0V, On (1) = 24V
OFF (0) = 0V, On (1) = 24V
8.30
Open collector output
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV PT US RW BU PS
1
1
1
Default
Open-loop, Closed-loop vector, Servo,
Regen
OFF (0)
Update rate
Background read
Summary of Contents for unidrive sp
Page 419: ......
Page 420: ...0471 0002 10 ...