Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
Menu 21
Unidrive SP Advanced User Guide
361
Issue Number: 10 www.controltechniques.com
Pr
21.15
does not have an equivalent normal motor parameter, but shows when motor 2 is active.
21.13
Voltage offset
Drive modes
Open-loop
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
1
1
Range
Open-loop
0.0 to 25.0 V
Default
Open-loop
0.0
Normal
parameter
Open-loop
Pr
5.23
Update rate
Background read
21.14
Transient inductance (
σ
L
s
)
Drive modes
Open-loop, Closed-loop vector, Servo
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
3
1
1
1
1
Range
Open-loop, Closed-loop vector, Servo
0.000 to 500.000 mH
Default
Open-loop, Closed-loop vector, Servo
0.000
Normal
parameter
Open-loop, Closed-loop vector, Servo
Pr
5.24
Update rate
Background read
21.15
Motor 2 active
Drive modes
Open-loop, Closed-loop vector, Servo
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
1
Default
Open-loop, Closed-loop vector, Servo
1
Normal motor
parameter
Open-loop, Closed-loop vector, Servo
Pr
21.15
Update rate
Background write
21.16
Thermal time constant
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU
PS
1
1
1
1
Range
Open-loop, Closed-loop vector, Servo,
Regen
0.0 to 3000.0
Default
Open-loop,
Closed-loop vector,
Servo
Regen
89.0
20.0
89.0
Normal motor
parameter
Open-loop, Closed-loop vector, Servo,
Regen
Pr
4.15
Update rate
Background read
Summary of Contents for unidrive sp