This parameter displays the current module’s synchronization status.
This is used to control the motion sequence user program.
When this parameter is ON (1), the voltage on the Applications module’s digital input 0 (zero) is passed through to the drive’s internal Freeze line.
This can be seen by other classes of SM-Solutions modules. For further information on the Freeze Input refer to the
Applications Modules User
Guide
.
♣♥
When this parameter is set to zero a freeze occurs on the rising edge of the module’s DIGIN0. When it is set to 1 a freeze occurs on the falling
edge of the module’s DIGIN0. For further information on the Freeze Input refer to the
Applications Modules User Guide
.
♦
When this parameter is set to zero the module will freeze data when it sees a rising edge of a freeze pulse from the drive. When it is set to a 1 the
module will freeze data when it sees a falling edge of a freeze pulse from the drive. For further information on the Freeze Input refer to the
Applications Modules User Guide
.
The priority levels of different tasks may be changed with this parameter. The parameter is accessed in a bit-wise manner:
This parameter is dependant on what is running in the module i.e. Indexer
This parameter is dependant on what is running in the module i.e. Indexer
x.39
Inter-module Drive Sync Status
♦♣♥
Access
RW
Range
0/1
Default
0
Update Rate
NA
Synchronisation Status
Status
0
The synchronization master request is zero or another Solutions
Module is synchronization master.
1
The Solutions Module is synchronization master.
3
The Solutions Module is synchronization master, but the
synchronization frequency is out of specification or not present.
x.41
Indexer Control
Access
RW
Range
0/3
Default
0
Update Rate
NA
x.42
Pass Freeze Through to Drive
♣♥
Access
RW
Range
0/1
Default
0
Update Rate
Initialisation
x.43
Freeze Invert
♦♣♥
Access
RW
Range
0/1
Default
0
Update Rate
Initialisation
x.44
Task Priority Level
♦♣♥
Access
RW
Range
0 to 255
Default
0
Update Rate
Initialisation
Bit
Value
Meaning
0
♣♥
0
CTNet task priority is higher than Pos tasks priority.
1
CTNet task priority is lower than Pos tasks priority. This will reduce
the jitter of the POS tasks but could lead to the CTNet task being
starved
1
♦♣♥
0
Inter-option communication task priority is higher than the POS tasks.
1
Inter option communication task priority lower than the POS tasks.
2
♣♥
0
Turbo CTNet Disabled
1
Turbo CTNet Enabled
x.45
User Set-Up Parameter 1
♣
Access
RO
Range
N/A
Default
0
Update Rate
N/A
x.46
User Set-Up Parameter 2
♣
Access
RO
Range
N/A
Default
0
Update Rate
N/A