The Applications Module will only detect a change in parameter values after start-up or on restart after being reset.
The Module Code indicates the type of module that is installed in the corresponding slot.
301: SM-Applications module
302: SM-Applications Lite module
304: SM-Applications Plus module
305: SM-Applications Lite V2 module
Specifies the major revision number of the operating system of the Applications module. Use in conjunction with
Pr 81.51
to form the complete
version number.
Provides the run status of the user DPL program in the Applications module. The following values are defined:
Displays the free CPU resource as a percentage of the current background execution time calculated over 200ms.
Defines the address of this node for ANSI and Modbus communications protocols.
For the ANSI protocol the address range is 11 to 99 where the first digit is the group address and the second digit is the unit number. Both digits must
be in the range of 1-9. Zero is not permitted since it is used by the master for addressing groups of nodes.
This parameter has no effect if the EIA-RS485 mode is 25 (CTSync) or 26 (CTSync)
73
Fast parameter initialisation failure
Yes
No
No
74
Over-temperature
Yes
Yes
Yes
75
Hardware unavailable. The user program attempted to access unavailable hardware. e.g. if access is made to
digital I/O, RS485 port or CTNet on SM-Applications Lite module.
Yes
Yes
Yes
76
Module type cannot be resolved. Module is not recognized.
Yes
No
Not Run
77
Inter-Solutions Module comms error with module in slot 1.
Yes
Yes
Yes
78
Inter-Solutions Module comms error with module in slot 2.
Yes
Yes
Yes
79
Inter-Solutions Module comms error with module in slot 3.
Yes
Yes
Yes
80
Inter-Solutions Module comms error with module unknown slot.
Yes
Yes
Yes
81
•
Slot selected as the reference or feedback does not contain a position Solutions Module
•
Attempt to change the Reference source or the Feedback source in more than one task.
APC internal error. See parameter #81.38. This may be caused by one of the following:
•
CAM table too small
•
A change of too many CAM segments has occurred at the CAM table input
•
CAM is selected but size is zero
•
CAM absolute mode selected and Reset Index or Reset Position in segment is out of range
May
Yes
Yes
82
Communications to drive faulty.
May
Yes
Yes
x.01
Module Code
♦♣♥
Access
RO
Range
0 to 499
Default
N/A
Update Rate
N/A
x.02
Firmware Version - Major
♦♣♥
Access
RO
Range
00.00 to 99.99
Default
N/A
Update Rate
N/A
x.03
DPL Program Status
♦♣♥
Access
RO
Range
0 to 3
Default
0
Update Rate
1ms of change
Display
Value
Description
nonE
0
No DPL program present
StoP
1
DPL program is stopped
run
2
DPL program is running
triP
3
Run-time error. ERROR task running or
DPL program stopped
x.04
Available System Resource
♦♣♥
Access
RO
Range
0 to 100
Default
N/A
Update Rate
200ms
x.05
EIA-RS485 Address
♣♥
Access
RW
Range
0 to 255
Default
11
Update Rate
Initialisation
Error Code
Reason
Trip
Drive?
ERROR
task?
Prog
Halted?