Parameter
structure
Keypad and
display
Parameter
x.00
Parameter
description format
Advanced parameter
descriptions
Macros
Serial comms
protocol
Electronic
nameplate
Performance RFC mode
Menus 15 to 17
SM-Uni Enc Pl
Unidrive SP Advanced User Guide
271
Issue Number: 10 www.controltechniques.com
Used to define the simulated encoder output in SSI mode, refer to the
SM-Universal Encoder Plus User Guide
.
Used to define the simulated encoder output in SSI mode, refer to the
SM-Universal Encoder Plus User Guide
.
If Pr
x.49
is set to one, Pr
x.04
, Pr
x.05
and Pr
x.06
are not updated. If this parameter is zero, Pr
x.04
, Pr
x.05
and Pr
x.06
are updated normally.
The error status is provided so that the only one option error trip is required for each Solutions Module slot. If an error occurs, the reason for the error
is written to this parameter and the drive may produce a ‘SLX.Er’ trip, where x is the slot number. A value of zero indicates that the Solutions Module
has not detected an error, a non-zero value indicates that an error has been detected. (See Table 5-13 on page 253 for the meaning of the values in
this parameter for the SM-Universal Encoder Plus). When the drive is reset, this parameter is cleared for the relevant Solutions Module.
This Solutions Module includes a temperature monitoring circuit. If the PCB temperature exceeds 90
°
C (94
°
C
V03.02.00
or later), the drive fan is
forced to operate at full speed (for a minimum of 10s). If the temperature falls below 90
°
C (94
°
C
V03.02.00
or later), the fan can operate normally
again. If the PCB temperature exceeds 100
°
C, the drive is tripped and the error status is set to 74.
The SM-Universal Encoder Plus includes a processor with software. The software version is displayed in Pr
x.02
and Pr
x.51
in the form Pr
x.02
=
xx.yy and Pr
x.51
= zz.
Where:
xx specifies a change that affects hardware compatibility
yy specifies a change that affects product documentation
zz specifies a change that does not affect the product documentation
When a Solutions Module is installed that does not contain software, both Pr
x.02
and Pr
x.51
appear as zero.
When operating with an Issue 3 SM-Universal Encoder Plus Solutions Module, the software must be
V.03.xx.xx
. When operating with an Issue 4 SM-
Universal Encoder Plus Solutions Module, the software must be
V
.
04.xx.xx
Failure to comply with the above can result in Solutions Module failure.
x.47
SSI output turns
RW
Uni
US
Ú
0 to 16
Ö
16
Update rate: Background read
x.48
SSI output comms resolution
RW
Uni
US
Ú
0 to 32 bits
Ö
0
Update rate: Background read
x.49
Lock position feedback
RW
Bit
Ú
OFF (0) or On (1)
Ö
Update rate: Background write
x.50
Solutions Module error status
RO
Uni
NC
PT
Ú
0 to 255
Ö
Update rate: Background write
x.51
Solutions Module software sub-version
RO
Uni
NC
PT
Ú
0 to 99
Ö
Update rate: Write on power-up
NOTE