Holding the Up or Down key in the first method will cause the
parameters value to change more rapidly the longer the key is held, until
such time that the parameters maximum or minimum is reached.
However with the second method an increasing rate of change does not
take place when adjusting any other digit other than the least significant
digit since a digit can only have one of 10 different values. Holding the
Up or Down will cause an auto repeat and roll over to more significant
digits but the rate of change is unaltered. If the maximum or minimum is
exceeded when adjusting any other digit than the least significant one,
the maximum value will flash on the display to warn the user that the
maximum or minimum has been reached. If the user releases the Up or
Down key before the flashing stops the last in range value will re-appear
on the display. If the Up or Down key is held the display will stop flashing
after three seconds and the maximum value will be written to the
parameter.
Parameters can be set to 0 by pressing the Up and Down keys
simultaneously.
2.6 SM-Keypad Plus
All SM-Keypad Plus displays built after data code N10 have software
version 4.02.00 programmed and support 5 languages (English, French,
German, Spanish and Italian) in addition to a user defined parameter set.
This software also gives the user access to two menus for SM-Keypad
Plus. Menu 40 is for SM-Keypad Plus set up, menu 41 selects commonly
used parameters for quick browsing.
Keypads built prior to N10 only support one user defined extra
parameter set only.
The SM-Keypad Plus contains two menus, menu 40 and menu 41. The
parameters in these menus are listed below.
Table 2-1 Menu 40 parameter descriptions
Table 2-2 Menu 41 parameter descriptions
For more information about the SM-Keypad Plus, see the
SM-Keypad Plus User Guide
.
Parameter
Range(
Ú
)
Default(
Ö
)
Type
40.00 Parameter 0
0 to 32767
0
RW Uni
40.01 Language selection
English (0), Custom (1),
French (2), German (3),
Spanish (4), Italian (5)
English (0)
RW Txt
US
40.02 Software version
999999
RO Uni
PT
40.03 Save to flash
Idle (0), Save (1), Restore (2),
Default (3)
Idle (0)
RW Txt
40.04 LCD contrast
0 to 31
16
RW Uni
US
40.05
Drive and attribute database upload was
bypassed
Updated (0), Bypass (1)
RO Txt
PT
40.06 Browsing favourites control
Normal (0), Filter (1)
Normal (0)
RW Txt
40.07 Keypad security code
0 to 999
0
RW Uni
US
40.08 Communication channel selection
Disable (0), Slot1 (1), Slot2 (2),
Slot3 (3), Slave (4), Direct (5)
Disable (0)
RW Txt
US
40.09 Hardware key code
0 to 999
0
RW Uni
US
40.10 Drive node ID (Address)
0 to 255
1
RW Uni
US
40.11 Flash ROM memory size
4Mbit (0), 8Mbit (1)
RO Txt
PT US
40.19 String database version number
0 to 999999
RO Uni
PT
40.20 Screen saver strings and enable
None (0), Default (1), User (2)
Default (1)
RW Txt
US
40.21 Screen saver interval
0 to 600
120
RW Uni
US
40.22 Turbo browse time interval
0 to 200ms
50ms
RW Uni
US
Parameter
Range(
Ú
)
Default(
Ö
)
Type
41.00 Parameter 0
0 to 32767
0
RW Uni
41.01
to
41.50
Browsing filter source F01 to F50
Pr
0.00
to Pr
391.51
0
RW Uni
41.51 Browsing favourites control
Normal (0), Filter (1)
Normal (0)
RW Txt
RW
Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS
Power down save