Table 5-11 Hardware fault trips
HF fault
code
Reason for trip
01
CPU address error
02
DMAC address error
03
Illegal instruction
04
Illegal slot instruction
05
Undefined exception
06
Reserved exception
07
Watchdog failure
08
Level 4 crash
09
Heap overflow
10
Router error
11
Access to the EEPROM failed or incorrect EEPROMs
installed.
12
Main program stack overflow
13
The drive firmware is not compatible with the drive
hardware
14-16
Not used
17
Power circuit - Multi-module system thermistor short circuit
18
Power circuit - Multi-module system interconnect cable
error
19
Power circuit - temperature feedback multiplexer failure
20
Power circuit - identification code error
21
Power circuit - unrecognised frame size
22
Power circuit - multi-module frame size mismatch
23
Power circuit - multi-module voltage rating mismatch
24
Power circuit - unrecognised drive size
25
Current feedback offset error
26
Soft start relay failed to close, or soft start monitor failed, or
braking IGBT short circuit at power-up
27
Power circuit thermistor 1 fault
28
Power circuit thermistor 2 or 3 fault / Internal fan fault for
some drive sizes.
29
Control board thermistor fault
30
DCCT wired break trip from power module
31
Aux fan failure from power module or a module in a multi
module system that has not powered up
32
Power stage - identification and trip information serial code
error
10.30
Full power braking time
Drive modes
Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit
SP
FI
DE Txt VM DP
ND
RA NC NV PT US RW BU PS
2
1
1
1
Range
Open-loop, Closed-loop vector, Servo,
Regen
0.00 to 400.00 s
Default
Open-loop, Closed-loop vector, Servo,
Regen
See below
Update rate
Background read
Summary of Contents for unidrive sp
Page 419: ......
Page 420: ...0471 0002 10 ...