User Manual
Appendix H
GFK-1742F
Jan 2020
Using VersaPro with the DSM314
502
Figure 265: CAM Slave Master Source Selection
You also need to indicate to Axis #2, the rollover points for the Master axis position
reference. To do this, select the Axis #2 tab in hardware configuration. Input 49,999 into
the High Position Limit and 0 into the Low Position Limit data entry fields (Figure 266). Note
that since this is a Cyclic CAM, the master source high limit, by definition, must be one less
than the last point in the master data table. In this example, this is point 50,000. Thus, the
high limit is equal to 49,999. One way to envision this principle is to think of a Cyclic CAM
Master as a continuous circular strip where the first point on the strip is the same as the last
point on the strip. Thus, for this example, 50,000 is the same point as zero. While in this tab,
change the Home Mode: to Move + and OverTravel Switch to Disabled.