Local Logic Execution Time
453
Table 93: Axis 1 Local Logic Variable Execution Times
X- Not Applicable.
Local Logic Variable Name
Local Logic Execution Time (In Microseconds)
Read
Write
Strobe1_Level_1
1.40
X
Strobe2_Level_1
1.40
X
Positive_EOT_1
1.40
X
Negative_EOT_1
1.40
X
Home_Switch_1
1.40
X
Digital_Output1_1
X
1.80
Digital_Output3_1
X
1.80
Analog_Input1_1
0.80
X
Analog_Input2_1
0.80
X
Position_Loop_TC_1
X
0.30
Follower_Ratio_A_1
X
0.30
Follower_Ratio_B_1
X
0.30
Torque_Limit_1
X
0.30
Position_Increment_Cts_1
X
0.30
Velocity_Loop_Gain_1
0.80
0.20
Reset_Strobe1_1
X
1.70
Reset_Strobe2_1
X
1.70
Enable_Follower_1
X
1.70
Jog_Plus_1
X
1.70
Jog_Minus_1
X
1.70
FeedHold_1
X
1.70
Error_Code_1
0.80
X
Actual_Position_1
0.70
X
Strobe1_Position_1
0.80
X
Strobe2_Position_1
0.80
X
Actual_Velocity_1
0.80
X
Block_1
0.90
X
Commanded_Position_1
0.60
X
Position_Error_1
0.60
X
Commanded_Velocity_1
0.60
X
User_Selected_Data1_1
0.60
X
User_Selected_Data2_1
0.60
X
UnAdjusted_Actual_Position_Cts_1
0.80
X
UnAdjusted_Strobe1_Position_Cts_1
0.80
X
UnAdjusted_Strobe2_Position_Cts_1
0.80
X