5.19 Home Position. Home Position (User Units). The value assigned to Commanded
Position when a Find Home cycle completes.
5.20 Home Offset. Home Position Offset (User Units). A value added to or subtracted
from the servo’s final stopping point when a Find Home cycle completes.
Home
Offset adjusts the final servo stopping point relative to the encoder marker. See
chapter 6 for details on the home cycle. Default: 0.
5.21 Final Home Velocity. Final Home Velocity (User Units/second). The velocity at which
the servo seeks the final Home Switch transition and Encoder Marker pulse at the
end of a Find Home cycle. This velocity is also used for the home cycle MOVE+ and
MOVE- modes. See chapter 6 for details on the home cycle. Final Home Velocity
must be slow enough to allow a 10 millisecond (filter time) delay between the final
Home Switch transition and the Encoder Marker pulse. Default: 500
5.22 servo seeks the initial Home Switch transitions during the Find Home cycle when the
Home Mode is configured for HOMESW. If desired, Find Home Velocity can be set to
a high value to allow the servo to quickly locate the Home Switch. Default: 2000
5.23 Home Mode. Find Home Mode. The method used to find home during a Find Home
cycle. HOME SWITCH indicates that a Home Switch is to be monitored to Find Home.
MOVE+ and MOVE
–
specify direct positive and negative movement to the next
encoder marker at the Final Home Velocity.
See chapter 6, “Non
-Programmed
Motion,” for details on the Home Cycle, Home Switch,
move+, and Move- Modes.
Default: HOMESW.
5.24 Return Data 1 Mode and Offset, Return Data 2 Mode and Offset. These configuration
parameters allow alternate data to be reported in the User Selected Data 1 and User
Selected Data 2 %AI location for each axis. The alternate data includes information
such as Parameter memory contents and the DSM314 Firmware Revision.
There are two Return Data configuration parameters, a mode selection and an offset
selection. The mode parameter selects the Return Data type. The offset parameter
is only used when the Parameter Data mode (18h) is selected. Mode default = 0
(Torque Command). Offset default = 0. The following Return Data selections are
allowed: