User Manual
Appendix E
GFK-1742F
Jan 2020
Local Logic Execution Time
456
Table 95: Axis 3 Local Logic Variable Execution Times
X- Not Applicable.
Local Logic Variable Name
Local Logic Execution Time (In Microseconds)
Read
Write
Strobe1_Level_3
1.40
X
Strobe2_Level_3
1.40
X
Positive_EOT_3
1.40
X
Negative_EOT_3
1.40
X
Home_Switch_3
1.40
X
Digital_Output1_3
X
1.80
Digital_Output3_3
X
1.80
Analog_Input1_3
0.80
X
Analog_Input2_3
0.80
X
Reset_Strobe1_3
X
1.70
Reset_Strobe2_3
X
1.70
Error_Code_3
0.80
X
Actual_Position_3
0.70
X
Strobe1_Position_3
0.80
X
Strobe2_Position_3
0.80
X
Actual_Velocity_3
0.80
X
Axis_OK_3
1.40
X
Position_Valid_3
1.40
X
Strobe1_Flag_3
1.40
X
Strobe2_Flag_3
1.40
X
Table 96: Axis 4 Local Logic Variable Execution Times
X- Not Applicable.
Local Logic Variable Name
Local Logic Execution Time (In Microseconds)
Read
Write
Strobe1_Level_4
1.40
X
Strobe2_Level_4
1.40
X
Positive_EOT_4
1.40
X
Negative_EOT_4
1.40
X
Home_Switch_4
1.40
X
Digital_Output1_4
X
1.80
Digital_Output3_4
X
1.80
Analog_Input1_4
0.80
X
Analog_Input2_4
0.80
X