User Manual
Chapter 4
GFK-1742F
Jan 2020
Configuration
129
4.3.9
Advanced Tab Data
The Advanced Tab allows up to 16 custom tuning parameters and associated data to be
entered for each axis. Although the Advanced Tab has 16 rows for entering axis tuning
parameter data, the DSM314 Release 1.0 firmware only allows Entry rows 1 and 2 to be
used. The figure below shows data in the cells for Axis 1 on Entry rows 1 and 2. DSM firmware
version 3.0 or later removes this restriction.
Figure 61: Advanced Tab
Tuning Parameter 1: Sets Digital Encoder Resolution (for digital servos only). Settings other
than 0 result in a derating of the maximum supported motor speed. Note that, for settings
0 and 1, some motors’ maximum speed ratings are below the maximum suppo
rted speed
shown in the table. Range of allowable settings: 0
–
3. In Figure 61 above, Tuning Parameter
1 is set to a value of 2 for Axis 1.
Table 38: Tuning Parameter 1 Values
Tuning Parameter 1 Values Counts/Revolution Maximum Supported Motor Speed
0
8192
44001,2
1
16384
36622
2
32768
1831
3
65536
915
Note:
•
Default setting
•
Some motors’ maximum speed rating is lower than t
he value in the table
Tuning Parameter 3: Sets minimum velocity output (millivolts) for analog servos. Allowed
data range is 0 -1000 millivolts. The recommended setting is 5 - 10mv, or just enough to
make the servo pull in to +/- 1 count of position error. In Figure 4.2 above, Tuning
Parameter 3 is set to a value of 10 for Axis 1.