User Manual
Appendix A
GFK-1742F
Jan 2020
Error Reporting
378
Error Code
(hex)
Response Description
Error Type Possible Cause
97
Status Only
Local Logic Timeout Warning Module
The Local Logic program execution time is
close (greater than 275 Microseconds) to
the maximum allowable execution time
(300 Microseconds). Decrease the Local
Logic execution time by reducing the
number of Local Logic statements or by
modifying the program structure. Consult
Appendix E for more information on local
logic execution time.
98
Status Only
Local Logic Execute on First
Sweep Error
Module
The user attempted to execute Local Logic
on the first PLC sweep (e.g. if the Local Logic
enable Q bit is on when the PLC is switched
from Stop to Run Mode).
99
Status Only
Local Logic Invalid Program
Name or Not Enabled in
Configuration
Module
The Local Logic Program Name specified in
Hardware Configuration is not valid (or
empty) or Local Logic is not enabled in
Hardware Configuration.
9A
Stop Fast
Local Logic Stop Error (Per-
Axis)
Axis
A Local Logic Stop Fast Error occurred (error
codes 91-94).
Hardware Limit Switch Errors
A0
Stop Fast
Limit Switch (+) error
Axis
The Positive Overtravel Limit Switch input is
off. If Overtravel Limit switches are not used,
set the Overtravel Limit Switch configuration
to Disabled.
A1
Stop Fast
Limit Switch (
–
) error
Axis
The Negative Overtravel Limit Switch input
is off. If Overtravel Limit switches are not
used, set the Overtravel Limit Switch
configuration to Disabled.
Hardware Errors
A8
Stop Fast
Out of Sync error
Axis
Position Error has exceeded the Position
error limit. Possible sources for this error are:
1. Position error limit being set too low for
the application.
2. Feedback device being disconnected or
slipping on controlled device
3. Incorrect Feedback device wiring. (i.e.
positive rotation indicated as negative
by feedback device)
A9
Status Only
Loss of Position Feedback
Axis
A Quadrature Error has been detected on an
incremental quadrature encoder. Check the
encoder wiring and ensure that the encoder
is not operated beyond its rated speed.
B0-BE
See Table 81
Digital Servo Alarms, documented in Table
81