Chapter 3 Connections and Wiring
|
ASDA-A&A+ Series
Revision April 2009
3-27
Signal
DI
Code
Function
Pt
Pr
S
T
Sz
Tz Pt-S Pt-T Pr-S Pr-T S-T
CCWL 23
Forward inhibit limit
(contact b, normally
closed)
DI7 DI7 DI7 DI7 DI7 DI7
ORGP 24
Reference “Home”
sensor
TLLM 25
Torque limit - Reverse
operation (torque limit
function is valid only
when P1-02 is enabled)
TRLM 26
Torque limit - Forward
operation (torque limit
function is valid only
when P1-02 is enabled)
SHOM
27 Move to “Home”
INDEX0 28
Feed step selection input
0 (bit 0)
INDEX1 29
Feed step selection input
1 (bit 1)
INDEX2 30
Feed step selection input
2 (bit 2)
INDEX3 31
Feed step selection input
3 (bit 3)
INDEX4 32
Feed step selection input
4 (bit 4)
MD0 33
Feed
step
mode
input
0
MD1 34
Feed
step
mode
input
1
MDP0 35
Manually continuous
operation
MDP1 36
Manually single step
operation
JOGU 37
Forward
JOG
input
JOGD 38
Reverse
JOG
input
STEPU 39
Step up input (available
in Pr mode only)
STEPD 40
Step down input
(available in Pr mode
only)
STEPB 41
Step back input.
(available in internal auto
running mode only)
AUTOR
42 Auto run input
GNUM0 43
Electronic gear ratio
(Numerator) selection 0
[see P2-60~P2-62]
GNUM1 44
Electronic gear ratio
(Numerator) selection 1
[see P2-60~P2-62]
Call 1(800)985-6929 for Sales
deltaacdrives.com
Call 1(800)985-6929 for Sales