Chapter 7 Servo Parameters
|
ASDA-A&A+ Series
7-28
Revision April 2009
•
D: Source of pulse command
Setting
value
Input pulse interface
Max. input pulse
frequency
Remark
Line driver
500Kpps
0
Open collector
200Kpps
CN1 Terminal Identification:
PULSE, /PULSE, SIGN, /SIGN
1
Line driver for
high-speed pulse
4Mpps
CN1 Terminal Identification:
HPULSE, /HPULSE, HSIGN,
/HSIGN
NOTE
1) High-speed pulse function (max. input pulse frequency 4Mpps) is for ASDA-A+ only.
P1 - 01
●
CTL
Control Mode and Output Direction
Communication Addr.: 0101H
Default: 00
Related Section:
Applicable Control Mode: ALL
Section 6.1
Unit: pulse (P mode), r/min (S mode), N-m (T mode)
Range: 0 ~ 1110
Settings:
not used
A
B
C
•
A: Control mode settings
•
B: Torque output direction settings
Control mode settings:
Pt
Pr
S
T
Sz
Tz
00
▲
01
▲
02
▲
03
▲
04
▲
05
▲
06
▲
▲
07
▲
▲
08
▲
▲
09
▲
▲
10
▲
▲
Torque output direction settings:
0
1
Forward
Reverse