Chapter 7 Servo Parameters
|
ASDA-A&A+ Series
Revision April 2009
7-57
P2 - 21
DO4
Digital Output Terminal 4 (DO4)
Communication Addr.: 0215H
Default: 105
Related Section:
Applicable Control Mode: ALL
Table 7.B
Unit: N/A
Range: 0 ~ 112
Settings: See P2-18 for explanation.
P2 - 22
DO5
Digital Output Terminal 5 (DO5)
Communication Addr.: 0216H
Default: 7
Related Section:
Applicable Control Mode: ALL
Table 7.B
Unit: N/A
Range: 0 ~ 112
Settings: See P2-18 for explanation.
P2 - 23
NCF
Notch Filter (Resonance Suppression)
Communication Addr.: 0217H
Default: 1000
Related Section:
Applicable Control Mode: ALL
Section 6.3.7
Unit: Hz
Range: 50 ~ 1000
Settings:
This parameter is used to set resonance frequency of mechanical system. It can be used to
suppress the resonance of mechanical system. If P2-24 is set to 0, this parameter is disabled.
P2 - 24
DPH
Notch Filter Attenuation Rate
(Resonance Suppression)
Communication Addr.: 0218H
Default: 0
Related Section:
Applicable Control Mode: ALL
Section 6.3.7
Unit: dB
Range: 0 ~ 32
Settings: 0: Disabled
Call 1(800)985-6929 for Sales
deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com