Chapter 12 Application Examples
|
ASDA-A&A+ Series
12-26
Revision April 2009
When the setting value of the time listed below is set to zero(0), the relative position will be ignored.
Positioning Point
Position Command Register
Moving Speed Register
Dwell Time Register
INDEX1
( P1-15, P1-16 )
P2-36 (V1)
P2-52 (T1)
INDEX2
( P1-17, P1-18 )
P2-37 (V2)
P2-53 (T2)
INDEX3
( P1-19, P1-20 )
P2-38 (V3)
P2-54 (T3)
INDEX4
( P1-21, P1-22 )
P2-39 (V4)
P2-55 (T4)
INDEX5
( P1-23, P1-24 )
P2-40 (V5)
P2-56 (T5)
INDEX6
( P1-25, P1-26 )
P2-41 (V6)
P2-57 (T6)
INDEX7
( P1-27, P1-28 )
P2-42 (V7)
P2-58 (T7)
INDEX8
( P1-29, P1-30 )
P2-43 (V8)
P2-59 (T8)
Digital I/O Signal Setting
DI Signal
Parameter Setting
Explanation
DI1 (SON)
P2-10 = 101
Servo ON
DI2 (AUTOR)
P2-11 = 142
Auto run input
DI3 (STEPD)
P2-12 = 140
Step down input
(STEPU) P2-12
=
139
Step up input
(STEPB) P2-12
=
141
Step back input.
DI4 (SHOM)
P2-13 = 127
Move to “Home”
DI5 (ORGP)
P2-14 = 124
Reference “Home” sensor
DI6 (CWL)
P2-15 = 22 (contact “b”)
Reverse Inhibit limit
DI7 (CCWL)
P2-16 = 23 (contact “b”)
Forward Inhibit limit
DI8 (EMGS)
P2-17 = 21 (contact “b”)
Emergency stop
DO Signal
Parameter Setting
Explanation
DO1 P2-18
=
101
DO2 P2-19
=
103
DO3 P2-20
=
109
DO4 P2-21
=
105
DO5 P2-22
=
107
Please refer to “Definition of DO Signals” in the
following section.