Chapter 3 Connections and Wiring
|
ASDA-A&A+ Series
3-26
Revision April 2009
Table 3.G Default DI signals and Control modes
Signal
DI
Code
Function
Pt
Pr
S
T
Sz
Tz Pt-S Pt-T Pr-S Pr-T S-T
SON
01 Servo
On
DI1 DI1 DI1 DI1 DI1 DI1 DI1 DI1 DI1 DI1 DI1
ARST 02
Alarm
Reset
DI5 DI5 DI5 DI5 DI5 DI5
GAINUP 03
Gain switching in speed
and position mode
CCLR 04
Pulse
clear
(see
P2-50)
DI2
DI2
DI2
ZCLAMP 05 Zero speed CLAMP
CMDINV 06
Command input reverse
control
HOLD 07
Position command
pause (Internal position
control only)
CTRG 08
Command triggered
(available in Pr mode
only)
DI2
DI2
DI2
TRQLM
09
Torque
limit
enabled
DI2
DI2
SPDLM
10
Speed
limit
enabled
DI2
DI2
POS0 11
Position command
selection 0
DI3
DI3
DI3
POS1 12
Position command
selection 1
DI4
DI4
DI4
POS2 13
Position command
selection 2
SPD0 14
Speed command
selection 0
DI3
DI3
DI3 DI5 DI3
SPD1 15
Speed command
selection 1
DI4
DI4
DI4 DI6 DI4
TCM0 16
Torque command
selection 0
DI3
DI3
DI3
DI3 DI5 DI5
TCM1 17
Torque command
selection 1
DI4
DI4
DI4
DI4 DI6 DI6
S-P 18
Position / Speed mode
switching (OFF: Speed,
ON: Position)
DI7
DI7
S-T 19
Speed / Torque mode
switching (OFF: Speed,
ON: Torque)
DI7
T-P 20
Torque / Position mode
switching (OFF: Torque,
ON: Position)
DI7
DI7
EMGS 21
Emergency stop (contact
b, normally closed)
DI8 DI8 DI8 DI8 DI8 DI8 DI8 DI8 DI8 DI8 DI8
CWL 22
Reverse inhibit limit
(contact b, normally
closed)
DI6 DI6 DI6 DI6 DI6 DI6
Call 1(800)985-6929 for Sales
deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com