BigIron RX Series Configuration Guide
1183
53-1001810-01
Displaying IPv6 MBGP information
46
This example shows how to display information for a specific neighbor, by specifying the neighbor’s
IPv6 address with the command. The number in the far left column indicates the neighbor for
which information is displayed. When you list information for multiple neighbors, this number
makes the display easier to read.
The Neighbor NLRI Negotiation section (shown in bold type) lists the types of routes that this
BigIron RX can exchange with the MBGP neighbor.
The TCP statistics at the end of the display show status for the TCP session with the neighbor. Most
of the fields show information stored in the BigIron RX’s Transmission Control Block (TCB) for the
TCP session between the BigIron RX and its neighbor. These fields are described in detail in
section 3.2 of RFC 793, “Transmission Control Protocol Functional Specification”.
Syntax: show ipv6 mbgp neighbors [
<ipv6-addr>
]
The
<ipv6-addr>
parameter specifies the neighbor’s IPv6 address.
BigIron RX # show ipv6 mbgp neighbor 4fee:2343:0:ee44::1
Total number of BGP Neighbors: 1
1 ipv6 Address: 8eff::0/32, Remote AS: 200 (IBGP), RouterID: 8.8.8.1
State: ESTABLISHED, Time: 0h33m26s, KeepAliveTime: 60, HoldTime: 180
KeepAliveTimer Expire in 9 seconds, HoldTimer Expire in 161 seconds
PeerGroup: mbgp-mesh
MD5 Password: $Gsig@U\
NextHopSelf: yes
RefreshCapability: Received
Messages: Open Update KeepAlive Notification Refresh-Req
Sent : 2 3264 17 0 0
Received: 1 1 34 0 0
Last Update Time: NLRI Withdraw NLRI Withdraw
Tx: --- --- Rx: --- ---
Last Connection Reset Reason:Unknown
Notification Sent: Unspecified
Notification Received: Unspecified
Neighbor NLRI Negotiation:
Peer Negotiated ipv6 multicast capability
Peer configured for ipv6 multicast Routes
TCP Connection state: ESTABLISHED, MD5-Password: ********
TTL check: 0, value: 0, rcvd: 64
Byte Sent: 284418, Received: 767
Local host: 166.1.1.1, Local Port: 179
Remote host: 166.1.1.2, Remote Port: 8137
ISentSeq: 2763573 SendNext: 3047992 TotUnAck: 0
TotSent: 284419 ReTrans: 0 UnAckSeq: 3047992
IRcvSeq: 3433336 RcvNext: 3434104 SendWnd: 65000
TotalRcv: 768 DupliRcv: 0 RcvWnd: 65000
SendQue: 0 RcvQue: 0 CngstWnd: 1440
Summary of Contents for Brocade DCX
Page 40: ...xl BigIron RX Series Configuration Guide 53 1001810 01 ...
Page 72: ...lxxii BigIron RX Series Configuration Guide 53 1001810 01 ...
Page 88: ...16 BigIron RX Series Configuration Guide 53 1001810 01 Searching and filtering output 1 ...
Page 300: ...228 BigIron RX Series Configuration Guide 53 1001810 01 Displaying IP information 7 ...
Page 318: ...246 BigIron RX Series Configuration Guide 53 1001810 01 Deploying a LAG 8 ...
Page 418: ...346 BigIron RX Series Configuration Guide 53 1001810 01 SuperSpan 12 ...
Page 482: ...410 BigIron RX Series Configuration Guide 53 1001810 01 MRP CLI example 14 ...
Page 506: ...434 BigIron RX Series Configuration Guide 53 1001810 01 Displaying VSRP information 15 ...
Page 582: ...510 BigIron RX Series Configuration Guide 53 1001810 01 Viewing Layer 2 ACLs 20 ...
Page 634: ...562 BigIron RX Series Configuration Guide 53 1001810 01 Troubleshooting ACLs 21 ...
Page 642: ...570 BigIron RX Series Configuration Guide 53 1001810 01 Trunk formation 22 ...
Page 746: ...674 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIP filters 24 ...
Page 808: ...736 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPF information 25 ...
Page 938: ...866 BigIron RX Series Configuration Guide 53 1001810 01 Displaying MBGP information 27 ...
Page 950: ...878 BigIron RX Series Configuration Guide 53 1001810 01 Using secure copy 28 ...
Page 988: ...916 BigIron RX Series Configuration Guide 53 1001810 01 Clearing IS IS information 29 ...
Page 1054: ...982 BigIron RX Series Configuration Guide 53 1001810 01 Sample 802 1x configurations 33 ...
Page 1108: ...1036 BigIron RX Series Configuration Guide 53 1001810 01 sFlow 39 ...
Page 1190: ...1118 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIPng information 44 ...
Page 1270: ...1198 BigIron RX Series Configuration Guide 53 1001810 01 Displaying ACLs 47 ...
Page 1310: ...1238 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPFv3 information 48 ...
Page 1382: ...1310 BigIron RX Series Configuration Guide 53 1001810 01 Commands That Require a Reload D ...
Page 1435: ...BigIron RX Series Configuration Guide 1363 53 1001810 01 VSRP E ...
Page 1436: ...1364 BigIron RX Series Configuration Guide 53 1001810 01 VSRP E ...