BigIron RX Series Configuration Guide
477
53-1001810-01
Configuring packet drop priority using WRED
18
Lower Wq values cause the avg-q-size to lean towards the statistical average queue size, reducing
WRED's sensitivity to the current state of the queue and thus reduce WRED's effectiveness. On the
other hand, higher Wq values cause the avg-q-size to lean towards the instantaneous queue size,
which exposes WRED to any change in the instantaneous queue size and thus may cause WRED to
overreact in cases of bursts. Thus, the value of Wq should be carefully chosen according to the
application at hand.
Calculating packets that are dropped
The Pdrop value, as calculated in the following equation, is the probability that a packet will be
dropped in a congested switch.
Using WRED with rate limiting
When rate limiting is configured on a device, it directs the switch to drop traffic indiscriminately
when the configured average-rate and maximum-burst thresholds are exceeded. If rate limiting is
configured with WRED, the traffic that exceeds these thresholds can be subjected to the WRED
algorithm which drops packets selectively by priority.
In this configuration, packets that exceed the thresholds established by the rate limiting
configuration are marked as either exceeding the average-rate or maximum-burst threshold. This
marking is then used to select a WRED configuration that determines which packets to drop.
Configuring packet drop priority using WRED
For a description of WRED, refer to
“Determining packet drop priority using WRED”
on page 475.
This section describes how to configure the parameters described in that section to enable the use
of WRED on a
device
.
To configure WRED, you must configure the following parameters:
•
“Enabling WRED”
•
“Setting the averaging-weight (Wq) parameter”
•
“Configuring the drop precedence parameters”
Enabling WRED
WRED must be enabled on any forwarding queue that you want it to operate on. To enable WRED
for the forwarding queue 3, enter the following command.
BigIron RX(config)#qos queue-type 3 wred enable
Syntax: [no] qos queue-type <queue-number> wred enable
pkt-size
(avg-q-size - min-avg-q size)
Pdrop =
-----------------
* Pmax * -----------------------------------------
pkt-size-max
(max-avg-q-size - min-avg-q size)
Summary of Contents for Brocade DCX
Page 40: ...xl BigIron RX Series Configuration Guide 53 1001810 01 ...
Page 72: ...lxxii BigIron RX Series Configuration Guide 53 1001810 01 ...
Page 88: ...16 BigIron RX Series Configuration Guide 53 1001810 01 Searching and filtering output 1 ...
Page 300: ...228 BigIron RX Series Configuration Guide 53 1001810 01 Displaying IP information 7 ...
Page 318: ...246 BigIron RX Series Configuration Guide 53 1001810 01 Deploying a LAG 8 ...
Page 418: ...346 BigIron RX Series Configuration Guide 53 1001810 01 SuperSpan 12 ...
Page 482: ...410 BigIron RX Series Configuration Guide 53 1001810 01 MRP CLI example 14 ...
Page 506: ...434 BigIron RX Series Configuration Guide 53 1001810 01 Displaying VSRP information 15 ...
Page 582: ...510 BigIron RX Series Configuration Guide 53 1001810 01 Viewing Layer 2 ACLs 20 ...
Page 634: ...562 BigIron RX Series Configuration Guide 53 1001810 01 Troubleshooting ACLs 21 ...
Page 642: ...570 BigIron RX Series Configuration Guide 53 1001810 01 Trunk formation 22 ...
Page 746: ...674 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIP filters 24 ...
Page 808: ...736 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPF information 25 ...
Page 938: ...866 BigIron RX Series Configuration Guide 53 1001810 01 Displaying MBGP information 27 ...
Page 950: ...878 BigIron RX Series Configuration Guide 53 1001810 01 Using secure copy 28 ...
Page 988: ...916 BigIron RX Series Configuration Guide 53 1001810 01 Clearing IS IS information 29 ...
Page 1054: ...982 BigIron RX Series Configuration Guide 53 1001810 01 Sample 802 1x configurations 33 ...
Page 1108: ...1036 BigIron RX Series Configuration Guide 53 1001810 01 sFlow 39 ...
Page 1190: ...1118 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIPng information 44 ...
Page 1270: ...1198 BigIron RX Series Configuration Guide 53 1001810 01 Displaying ACLs 47 ...
Page 1310: ...1238 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPFv3 information 48 ...
Page 1382: ...1310 BigIron RX Series Configuration Guide 53 1001810 01 Commands That Require a Reload D ...
Page 1435: ...BigIron RX Series Configuration Guide 1363 53 1001810 01 VSRP E ...
Page 1436: ...1364 BigIron RX Series Configuration Guide 53 1001810 01 VSRP E ...