BigIron RX Series Configuration Guide
85
53-1001810-01
Configuring TACACS/ security
4
3. Set optional parameters. Refer to
“Setting optional TACACS/ parameters”
on page 86.
4. Configure authentication-method lists. Refer to
“Configuring authentication-method lists for
TACACS/”
on page 88.
5. Optionally configure authorization. Refer to
“Configuring authorization”
on
page 89.
6. Optionally configure accounting. Refer to
“Configuring accounting”
on
page 92.
Enabling SNMP to configure TACACS/TACACS
TACACS is disabled by default. To enable SNMP access to TACACS MIB objects on the device, enter
the following command.
BigIron RX(config)#enable snmp config-tacacs
Syntax: [no] enable snmp <config-radius | config-tacacs>
The <config-radius> parameter specifies the RADIUS configuration mode. Radius is disabled by
default.
The <config-tacacs> parameter specifies the TACACS configuration mode. TACACS is disabled by
default.
Identifying the TACACS/ servers
To use TACACS/ servers to authenticate access to a device, you must identify the servers
to the device.
For example, to identify three TACACS/ servers, enter commands such as the following.
BigIron RX(config)# tacacs-server host 207.94.6.161
BigIron RX(config)# tacacs-server host 207.94.6.191
BigIron RX(config)# tacacs-server host 207.94.6.122
Syntax: tacacs-server host <ip-addr> |<hostname> [auth-port <number>]
The <ip-addr> |<hostname> parameter specifies the IP address or host name of the server. You
can enter up to eight tacacs-server host commands to specify up to eight different servers.
NOTE
To specify the server's host name instead of its IP address, you must first identify a DNS server using
the ip dns server-address <ip-addr> command at the global CONFIG level.
If you add multiple TACACS/ authentication servers to the device, the device tries to reach
them in the order you add them. For example, if you add three servers in the following order, the
software tries the servers in the same order.
1. 207.94.6.161
2. 207.94.6.191
3. 207.94.6.122
You can remove a TACACS/ server by entering no followed by the tacacs-server command.
For example, to remove 207.94.6.161, enter the following command.
BigIron RX(config)# no tacacs-server host 207.94.6.161
Summary of Contents for Brocade DCX
Page 40: ...xl BigIron RX Series Configuration Guide 53 1001810 01 ...
Page 72: ...lxxii BigIron RX Series Configuration Guide 53 1001810 01 ...
Page 88: ...16 BigIron RX Series Configuration Guide 53 1001810 01 Searching and filtering output 1 ...
Page 300: ...228 BigIron RX Series Configuration Guide 53 1001810 01 Displaying IP information 7 ...
Page 318: ...246 BigIron RX Series Configuration Guide 53 1001810 01 Deploying a LAG 8 ...
Page 418: ...346 BigIron RX Series Configuration Guide 53 1001810 01 SuperSpan 12 ...
Page 482: ...410 BigIron RX Series Configuration Guide 53 1001810 01 MRP CLI example 14 ...
Page 506: ...434 BigIron RX Series Configuration Guide 53 1001810 01 Displaying VSRP information 15 ...
Page 582: ...510 BigIron RX Series Configuration Guide 53 1001810 01 Viewing Layer 2 ACLs 20 ...
Page 634: ...562 BigIron RX Series Configuration Guide 53 1001810 01 Troubleshooting ACLs 21 ...
Page 642: ...570 BigIron RX Series Configuration Guide 53 1001810 01 Trunk formation 22 ...
Page 746: ...674 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIP filters 24 ...
Page 808: ...736 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPF information 25 ...
Page 938: ...866 BigIron RX Series Configuration Guide 53 1001810 01 Displaying MBGP information 27 ...
Page 950: ...878 BigIron RX Series Configuration Guide 53 1001810 01 Using secure copy 28 ...
Page 988: ...916 BigIron RX Series Configuration Guide 53 1001810 01 Clearing IS IS information 29 ...
Page 1054: ...982 BigIron RX Series Configuration Guide 53 1001810 01 Sample 802 1x configurations 33 ...
Page 1108: ...1036 BigIron RX Series Configuration Guide 53 1001810 01 sFlow 39 ...
Page 1190: ...1118 BigIron RX Series Configuration Guide 53 1001810 01 Displaying RIPng information 44 ...
Page 1270: ...1198 BigIron RX Series Configuration Guide 53 1001810 01 Displaying ACLs 47 ...
Page 1310: ...1238 BigIron RX Series Configuration Guide 53 1001810 01 Displaying OSPFv3 information 48 ...
Page 1382: ...1310 BigIron RX Series Configuration Guide 53 1001810 01 Commands That Require a Reload D ...
Page 1435: ...BigIron RX Series Configuration Guide 1363 53 1001810 01 VSRP E ...
Page 1436: ...1364 BigIron RX Series Configuration Guide 53 1001810 01 VSRP E ...