A
Cisco SPA 500 Series and WIP310 IP Phone Administration Guide
193
Creating an LED Script
LED Script
The LED script describes the color and blinking pattern of a Line Key LED. Each
script contains a number of fields separated by a semicolon(;). White spaces are
ignored. Each field has the syntax <
field-name
> = <
field-value
>. The allowed
field-name
and corresponding
field-values
are listed below:
c
=o|r|g|a
This field sets the color of the LED. The 4 choices are:
•
o = off
•
r = red
•
g = green
•
a = amber (orange)
p
=n[b]|s[b]|f[b]|d[b]|u[d]
This field sets the blinking pattern of the LED. The 4 choices are:
•
nb = no blink (steady on or off)
•
sb = slow blink (1s on and 1s off)
•
fb = fast blink (100ms on and 100ms off)
•
ud = user-defined (according to the contents of the u field)
u=on/off/on/off/etc.
This is a user-defined blinking pattern used only when p = ud. It consists of up to 4
pairs of on/off duration in seconds with up to 2 decimal places; each value is
separated by a forward slash (/).