10) Pull out the main heater and the sub heater from the fixing assembly to the front with
care not to damage them.
When opening the fixing upper unit during inspection/maintenance work, you could
cause the side plate of the upper fixing unit to push down the height adjusting
support plate of the fixing assembly inlet guide, lowering the fixing assembly inlet
guide. Since such a condition will lead to jamming of copy paper, make sure not to
open the fixing assembly upper unit with force.
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 6 FIXING SYSTEM
6-26
Caution: