18. The copy is blurred and fuzzy.
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 11 TROUBLESHOOTING
11-82
Cause
Scanner drive
cable
Scanner rail
Photosensitive
drum
Drum drive
gear
Developing
gear
Cleaner
assembly gear
Drum drive
system
Checks
Is the cable overlapping on the
cable pulley while the scanner is
moving, or is the cable too slack
or taut?
Move the No. 1 mirror mount by
hand. Does it move smoothly?
Does the problem occur at
intervals of about 25 cm?
Does the problem occur at
intervals of about 3 mm?
Does the problem occur at
intervals of about 6 mm?
Does the problem occur at
intervals of about 6 mm?
Step
1
2
3
4
5
6
YES/NO
YES
NO
YES
YES
YES
YES
NO
Action
1. Route the cable once
again.
2. If cable is twisted or
frayed, replace it.
Clean the surface of the
scanner rail with alcohol.
Thereafter, apply a small
amount of lubricant.
1. Check the drum gear.
2. Check the ends of the
drum (in contact with
the developing rolls)
for scraches and
protrusions.
Check the drum drive
gear.
Check the developing
assembly.
Check the cleaner
assembly.
Check the drum drive
system.