4) Turn the magnet roller clockwise (viewing from the front).
5) When a full coating has developed in the area from which toner was removed in step
3), repeat steps 3) through 5).
N. Separation Claw/Separation Claw Drive Assembly
1. Removing from the Drum Unit
1) Remove the process unit from the copier. (See p. 7-18.)
1. Take care not to bend the separation claw.
2. Take care not to damage the photosensitive drum.
2) Remove the screw
q
, and remove the No. 2 insulating plate
w
.
3) Remove the screw
e
, and remove the claw holder
r
.
Figure 4-356
e
e
r
q
w
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)