41. The blanking exposure lamp fails to turn on.
42. The pre-exposure lamp fails to turn on.
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 11 TROUBLESHOOTING
11-109
Cause
DC controller
PCB
Blanking
exposure lamp
DC controller
PCB
Checks
Remove the blanking exposure
lamp, and connect the connector.
Select ‘BLANK’ in service mode
(
). Does the blanking
exposure lamp turn on when the
user mode key is pressed?
Replace the blanking exposure
lamp. Does the new lamp turn on
correctly?
]
4
]
Step
1
2
YES/NO
YES
YES
NO
Action
Check the wiring from
the blanking exposure
lamp to the DC controller
PCB; if normal, replace
the DC controller PCB.
End.
Check the wiring from
the blanking exposure
lamp to the DC controller
PCB; if normal, replace
the DC controller PCB.
Cause
DC controller
PCB
Pre-exposure
lamp PCB
Checks
Set the meter to the 30VDC
range. Does the voltage between
J103B-2 (–) and GND change
from 24 to 0 V when the Copy
Start key is pressed?
Step
1
YES/NO
NO
YES
Action
Replace the DC
controller PCB.
Check the wiring from
the DC controller PCB to
the pre-exposure lamp
PCB; if normal, replace
the pre-exposure lamp.