4) Remove the two mounting screws
e
used to hold the fixing cleaning belt assembly
in place, and open the fixing cleaning belt upper assembly
r
upward.
Figure 6-205
5) Remove the cleaning belt feeding roller
t
and the cleaning belt take-up roller
y
by
pushing them toward the rear.
Figure 6-206
Be sure to remove the silicone oil collecting in the oil pan found under the cleaning
belt feeding roller.
t
y
e
r
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 6 FIXING SYSTEM
6-21
Caution: