Screen 1-5
*1: No data is used to represent alarm in the machine.
*2: For ‘B-ER’, the four bits to the right of 1–3 remain ‘0000’, and no E code is indicated.
*3: For ‘B-JAM’, JAM associated with the RDF is limited to ‘0700’. For details, see the next screen (DF-
JAM).
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 11 TROUBLESHOOTING
11-167
5/9
Item
B-JAM0
B-JAM3
B-JAM6
B-ALRM
*1
B-ER1
*2
B-ER2
*2
B-ER3
*2
A
B
Description
Indicates the locations of the most recent and the sec-
ond most recent jams that occurred in the machine.
Indicates the locations of the third, fourth, and fifth
most recent jams that occurred in the machine.
Indicates the sixth, seventh, and eighth most recent
jams that occurred in the machine.
Not used.
Indicates the most recent self diagnosis code for the
machine (excluding RDF).
Indicates the second most recent self diagnosis code
for the machine (excluding RDF).
Indicates the third most recent self diagnosis code for
the machine (excluding RDF).
Indicates a type of E002 (temperature of fixing roller
fails to reach specific value within specific time).
Indicates the type of thermistor that detected E001
(temperature of fixing roller exceeded specific value).
Remarks
See Table 11-703.
*3
See Table 11-703.
See Table 11-703.
1: 70° to 100°C
2: 100° to 150°C
1: main thermistor
(TH1)
2: sub thermistor
(TH2)