Figure 4-114
The transfer corona current is varied in relation to the temperature and the humidity
measured by the environment sensor to eliminate the effects of changes in the
environment.
Figure 4-115
2. Turning On and Off the Separation/Pre-Transfer Corona Current
The separation/pre-transfer corona current is turned on and off when all outputs of
the HVTAC drive signal (HVP.POST.AC), roller electrode rive signal (ROED), and high-
voltage DC drive signal (DCON) generated by the DC controller PCB go ‘1’.
Humidity (%)
Pre-transfer current (-)
Temperature (°C)
Drum surface potential
"high"
Drum surface potential
"medium"
Drum surface potential "low"
Separation current (-)
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 4 IMAGE FORMATION SYSTEM
4-16