12. Removing the Separation Belt Assembly
1) Remove the feeding roller/separation belt assembly.
2) Remove the stop ring
q
and the bushing
w
at the front.
Figure 5-890
3) Lift the front of the separation belt assembly, and shift it to the rear; then, remove the
separation belt assembly.
4) Detach the belt from the separation belt assembly.
13. Adjusting the Pressure of the Separation Roller of the Holding tray
Turn the separation roller adjusting roll so that the distance to the shaft is 32.7
±0.1 mm.
Figure 5-891
32.7±0.1mm
q
w
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 5 PICK-UP/FEEDING SYSTEM
5-111