16. Removing the Holding Tray X Motor
1) Remove the side guide plate assembly.
2) Remove the mounting screw, and remove the motor cover.
3) Remove the two mounting screws
q
, and disconnect the connector; then, remove
the motor
w
.
Figure 5-894
17. Removing the Holding Tray Re-Circulating Motor
1) Remove the side guide plate assembly.
2) With the paper jogging guide plate fully open, mark the position of the paper jogging
guide plate assembly with a pencil or the like. (See Figure 5-900.)
3) Remove the three mounting screws
q
, and disconnect the connector
w
; then,
remove the rear guide plate assembly
e
.
Figure 5-895
q
q
w
e
q
w
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 5 PICK-UP/FEEDING SYSTEM