![Canon NP6251 Service Manual Download Page 339](http://html.mh-extra.com/html/canon/np6251/np6251_service-manual_59699339.webp)
6) Remove the mounting screw
e
, and shift the thermistor assembly
r
to the right to
remove.
Figure 6-224
7) Remove the mounting screw
t
and two retaining screws
y
, and remove the main
thermistor
u
.
Figure 6-225
12. Removing the Lower Separation Claw Assembly
1) Slide out the fixing/feeding unit from the copier.
2) Remove the fixing/feeding assembly front cover.
3) Remove the flywheel.
4) Remove the fixing assembly upper cover.
5) Remove the fixing cleaning belt, clean the silicone oil pan; then, remove the fixing
assembly upper unit.
6) Remove the two mounting screws
q
, and remove the lower separation claw
assembly 2 together with its support plate
w
.
Figure 6-226
q
q
w
t
y
y
u
e
r
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 6 FIXING SYSTEM
6-31