CHAPTER 11 TROUBLESHOOTING
11-86
Cause
Environment
Main thermistor
(TH1)
DC controller
PCB
Checks
Does the problem occur only
when the machine is turned on for
the first time in the morning?
Replace the thermistor. Is the
problem corrected?
Step
6
7
YES/NO
YES
YES
NO
Action
•Advise the user that the
site is out of
specification.
•Advise the user not to
turn on the machine
until the room is warm
enough.
End.
Replace the DC
controller PCB.
Cause
Thermistor
(TH1/TH2)
DC controller
PCB
AC driver
DC controller
PCB
Checks
Execute ‘ERROR’ in service mode
(
), and open the front door
and the delivery assembly to cool
the fixing roller. Is ‘E001’ indicated
immediately after power-on when
the power switch is turned on?
Turn off the power switch, and
slide out the fixing feeding
assembly. Disconnect the relay
connector J2757 from inside the
fixing unit, and set the meter to
the 1K
Ω
range. Connect the probe
to the terminal of the harness on
the thermistor side. Is the reading
about 0
Ω
at this time? (After the
check, be sure to connect J2757.)
Replace the AC driver. Is the
problem corrected?
]
4
]
Step
1
2
3
YES/NO
NO
YES
NO
YES
NO
Action
Go to step 3.
Replace the thermistor.
Replace the DC
controller PCB.
End.
Check the wiring from
the AC drive to the DC
controller; if normal,
replace the DC controller
PCB.