![Canon NP6251 Service Manual Download Page 47](http://html.mh-extra.com/html/canon/np6251/np6251_service-manual_59699047.webp)
2. Basic Sequence of Operations at Power-On (2/2)
When the surface temperature of the fixing roller is 75°C or less and, in addition, the
ambient temperature is 17°C or less at power-on,
Figure 2-104
Charging wire
cleaning motor
INTR
Power
ON
Fixing sub heater
(H2)
Main motor (M1)
Primary charging
assembly
Developing bias DC
Developing bias AC
Pre-transfer charging
assembly DC
Pre-transfer charging
assembly AC
Transfer charging
assembly
Separation charging
assembly DC
Separation charging
assembly AC
Pre-exposure LED
Blanking exposure
LED
Fixing main heater
(H1)
Surface potential
control
Scanning lamp (LA1)
V
D
V
L1
V
L2
WMUP
195°C
(200°C)
CNTR1
CNTR2
LSTR
STBY
200°C
(205°C)
WMUPR
Controlled to 200°C
(210°C)
■
Differences from Sequence 1/2
• WMUPR is executed until the surface temperature of the fixing roller reaches 200°C (210°C)
without ending LSTR in 10 sec after potential control (CNTR1, CNTR2).
• The surface temperature of the fixing roller is 75°C or less at power-on and the ambient
temperature is 17°C or less for the value within parentheses; for the value outside
parentheses, if the surface temperature of the fixing roller is 75°C or more.
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV.0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 2 BASIC OPERATION
2-5