2. Removing the Lens Stage Temporarily
1) Remove the copyboard glass.
2) Move the No. 1 mirror mount to the left of the scanner rail.
Be sure to push the center of the No. 1 mirror mount.
3) Remove the lens hood.
4) Remove the mounting screw of the Y direction cable metal clamp; then, fix the end
of the Y direction cable temporarily in place.
5) Remove the mounting screw
q
, and remove the light-blocking belt retainer
w
(on
lens mount).
Figure 3-519
6) Remove the mounting screw
e
, and remove the light-blocking curtain 2 (front)
r
together with the holder. (Fix the light-blocking belt mount temporarily in place with
tape to the lens stage.)
Figure 3-520
r
e
w
q
COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 3 EXPOSURE SYSTEM
3-34