COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 11 TROUBLESHOOTING
11-162
Item
FTMP
RTMP
RHUM
LMP1
LMP2
WIRE
PLMT
LLMT
Description
Indicates the surface temperature (output of thermistor
TH1) of the fixing roller.
Indicates the machine internal temperature (output of
temperature sensor on DC controller PCB).
Indicates the machine internal humidity (output of
humidity sensor on DC controller PCB).
Indicates the activation voltage of the scanning lamp
(100/120V model).
Indicates the activation voltage of the scanning lamp
(230V model).
Indicates a value other than ‘0’ if the primary, pre-
transfer, or transfer/separation charging wire cleaner
stops at a point other than home position. The cleaner
can at times return to home position when wire
cleaning is executed in user mode.
Indicates ‘1’ during current control of the primary
charging assembly or when the current has reached
the upper or the lower limit.
Indicates ‘1’ when the activation voltage of the
scanning lamp has reached the upper limit; ‘2’ when it
has reached the lower limit.
Remarks
Unit:°C
Unit: V
Unit: V
1: error
0: normal
0: normal
1: error
2: error
D. Display Mode (
)
Using the
or
key, select the appropriate screen.
Screen 1-1
]
1
]
1/9